We ensure on-time project delivery with responsive after-sales service, routine maintenance, and 24/7 technical support whenever needed.
Gas-Based Fire Suppression System
Clean, Fast & Damage-Free Fire Protection for Critical Areas
Gas-Based Fire Suppression Systems are specially designed for areas where water cannot be used. They extinguish fire rapidly using clean, residue-free gases, ensuring full protection of sensitive equipment, electronics, and mission-critical operations.
At VJ Fire Technology & Services, we design, install, test, and maintain complete CO₂, FM-200, and Novec 1230 Fire Suppression Systems, fully compliant with NBC and NFPA standards. Our solutions provide instant activation, minimal downtime, and maximum asset protection for high-value environments.
How Gas-Based Fire Suppression Works
- Fire detectors sense smoke, heat, or flame
- Fire Alarm Panel processes the signal
- Agent cylinders release gas through network piping
- Gas floods the protected zone uniformly
- Fire is extinguished within seconds
- System lockouts and alarms prevent re-entry (where required)
These systems ensure minimal downtime and maximum business continuity.
Components of a Gas-Based Suppression System
- Gas cylinders & storage rack
- Piping network
- Nozzle assemblies
- Fire detection & control panel
- Release mechanisms & actuators
- Manual release stations
- Warning alarms & safety interlocks
- Pressure switches & timers
All components are UL/FM/ISI certified for maximum reliability.
Types of Gas Based Fire Suppression System We Provide
01
CO₂ Fire Suppression System (Carbon Dioxide)
Fast response for machinery, electrical panels & industrial areas
CO₂ suppresses fire by oxygen displacement, reducing oxygen to a level where combustion cannot continue.
This system is highly effective for Class B & electrical fires, making it ideal for non-occupied spaces.
Key Benefits:
- Rapid fire suppression
- No residue or water damage
- Suitable for high-hazard industrial environments
- Ideal for machinery spaces, panel rooms & paint booths
Safety Note:
Requires complete evacuation before discharge.
02
FM-200 Fire Suppression System (HFC-227ea)
Clean, fast & safe suppression for occupied areas
FM-200 extinguishes fire by heat absorption and interrupts the combustion process — without harming equipment or people.
Key Benefits:
- Safe for occupied environments
- Zero residue, no downtime
- Extinguishes in 10 seconds
- Ideal for data centers, control rooms & telecom rooms
Complies with NFPA 2001 and global clean agent standards.
03
Novec 1230 Fire Suppression System (FK-5-1-12)
Environmentally sustainable clean agent protection
Novec 1230 offers the advanced, eco-friendly alternative to FM-200 — with the lowest global warming potential (GWP < 1) and zero ozone depletion.
Key Benefits:
- Ultra-fast suppression
- Environmentally responsible
- Safe for occupied spaces
- Protects sensitive electronics & valuable equipment
Ideal For:
Data centers, telecom hubs, labs, clean rooms, process control rooms, museums, libraries, archives, and heritage sites.
Key Features & Advantages
01
Instant suppression in under 10 seconds
02
Residue-free discharge — no cleanup required
03
Safe for electronics & high-value equipment
04
Eco-friendly (Novec 1230)
05
Engineered for critical & high-risk environments
06
Integrates with fire alarm & detection systems
07
NFPA, NBC & IS compliant
08
Minimal downtime, faster recovery
Our Services for Gas-Based Suppression Systems
At VJ Fire Technology & Services, we provide end-to-end gas-based suppression solutions, ensuring safety, compliance, and long-term reliability.
System Design & Engineering
- Hazard analysis
- Room integrity testing
- Hydraulic flow calculations
- Project-specific BOQ
- NFPA/NBC-compliant design
Supply of Certified Equipment
We supply premium clean agent cylinders, nozzles, valves, panels, control modules & accessories.
Installation & Commissioning
- Precise nozzle placement
- Control panel programming
- Gas discharge testing
- System leak test & calibration
Room Integrity Test (RIT)
Mandatory test for gas retention capability (for FM-200 / Novec 1230 rooms).
Assistance in Fire NOC documentation for Pune, PCMC, PMRDA, MIDC & national authorities.
AMC & Maintenance
- Cylinder pressure checks
- Panel health inspection
- Detector cleaning
- Nozzle alignment verification
- Refilling & servicing support
Applications
Our gas suppression systems are ideal for:
- Data Centers & Server Rooms
- UPS Rooms & Battery Rooms
- Control Rooms & Power Facilities
- Telecommunication Hubs
- Laboratories & Clean Rooms
- Museums, Archives & Libraries
- Industrial Machine Areas
- Paint Booths & Chemical Storage Rooms
Any space with high-value equipment or critical operations benefits from gas-based protection.
Standards We Follow
We comply with:
- NFPA 12 (CO₂ Systems)
- NFPA 2001 (Clean Agent Systems)
- NBC (National Building Code of India)
- TAC Guidelines
- ISO & UL/FM Standards
Why Choose VJ Fire Technology & Services
We believe fire safety is not just compliance — it’s a commitment to saving lives and ensuring continuity.
20+ Years of Fire Safety Expertise
Backed by decades of industry experience, our certified engineers deliver reliable, compliant, and high-performance fire protection systems.
End-to-End Fire Safety Solutions
From design and supply to installation, testing, commissioning, and AMC—we provide complete fire protection under one roof for maximum convenience.
Certified & Standards-Compliant Systems
All our systems follow NFPA, NBC & IS standards, ensuring long-term safety, reliable functioning, and seamless Fire NOC approvals.